ITEM: Fixed Hanger - 12mm DIA bolt hole
USAGE: For recreational climbing, industrial safety
and access systems. Theses hangers are
designed to be used as belay and lead point
anchors in conjunctions with the appropriate
expansion or chemically fixed bolt or stud
where continuous long-term loading is not
expected.
MATERIAL: 304 stainless steel plate
FABRICATION PROCESS: Laser cut with nitrogen, bent and tumbled from 3mm-plate stock
QUALITY
CONTROL:
Visual inspection of raw product and random testing of samples from each batch
PROTOTYPE AND
PRODUCTION TESTING:
Tensile load tests to destruction with random samples
TEST EQUIPMENT: All testing is subcontracted to A.Noble & sons. And is therefore tested on their hydraulic test station. Attachment of the hanger is by a 10mm DIA bolt and a 6mm DIA shackle.
TEST RESULTS: First visible distortion - 10 kN
Gross distortion (marked distortion of eye region 20-22 kN)
Rupture – 36KN
REMARKS: Failure is generally due to rupture of the eye region of the hanger after extensive distortion. (Up to 170% of its original length)
RECOMMENDATIONS: Suitable for use in rock climbing where UTS of 20 – 30 KN are required. For industrial use, safe working loads of 20 KN for tensile, shear and combined stress. Due to the failure mode encountered, and the nature of the intended use a safety factor of 1.5 is considered to be adequate. Prior to each use each hanger should be visually inspected. Any distortion or apparent damage to the hanger indicates that the hanger should not be used and should be removed or rendered un-usable.

 

Copyright ©2002 Adrenalin Climbing Equipment.
Adrenalin Guarantee | Liability Statement | Contact Us